Technical Specification

Voltage (V) : 230 - 400
Fluid temperature (°C) : 50 °C - (70 °C optional)
Operating pressure (bar) : 16 bar - (25 bar optional)
Delivery head H (m) : Refer to catalogue
Description

Highly efficient water-supply unit ready for connection (non self-priming). With 2 to 4 vertically arranged glanded stainless steel high-pressure multistage centrifugal pumps from the Helix V series connected in parallel, including Smart Controller SC (available with and without frequency converter FC).

Application

- Fully automatic water supply and pressure boosting in residential, commercial and public buildings, hotels, hospitals, department stores and for industrial systems.
- Pumping of potable water, process water, cooling water, fire water (apart from fire-extinguishing systems in accordance with DIN 14462) or other water mixtures that do not attack the materials used chemically or mechanically and do not contain abrasive or long-fibre constituents

Special features/product advantages

- Heavy-duty system with Helix V series stainless steel high-pressure multistage centrifugal pumps for all requirements contained in DIN 1988 (EN 806)
- High-efficiency pump hydraulics in conjunction with IE2 standard motors
- Hydraulics of entire system are pressure-loss optimised.
- 2- 6 vertical Helix V series high-pressure multistage centrifugal pumps switched in parallel
- "Smart" Controller: symbol-based LC display, simple navigation with a clear menu, rotary knob for easy setting of parameters. Communication-capable control device for monitoring the system operation, available with and without frequency converter for infinitely variable control of the base-load pump


Technical data

- Mains connection 3~230 V/400 V ± 10%, 50 Hz
- Max. fluid temperature 50 °C (70 °C optional)
- Max. ambient temperature of 40 °C
- Operating pressure 16 bar (25 bar optional)
- Inlet pressure 10 bar
- Nominal connection diameters on discharge side R 1½ ‐ DN 200
- Nominal connection diameter on the intake side R 1½" - DN 200
- Rated speed 2850 rpm
- Protection class IP 54 (SC control device)
- Fuse protection on mains side A, AC 3 according to motor power and EVU regulations
- Approved fluids (other fluids on request):
- Potable water and secondary hot water
- Cooling water
- Fire water
Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with DIN 1988 (EN 806)

Equipment/function

- 2-4 pumps per system of the Helix V 4 to Helix V 52 series with IE2 standard motor
- Automatic pump control via Smart Controller SC The Smart FC version is additionally equipped with a frequency converter in the switchbox
- Parts that come in contact with the fluid are corrosion-resistant
- Base frame made of galvanised steel, with height-adjustable vibration absorbers for insulation against structure-borne noise, cable guidance and integrated hoisting gear
- Check valve on the suction and pressure sides of each pump
- Non-return valve on the pressure side of each pump
- Diaphragm pressure vessel 8 l, PN16, pressure side (accessories)
- Pressure sensor, pressure side
- Pressure gauge, pressure side
- Optional low-water cut-out switchgear with pressure gauge, suction side


Description/design

- Base frame: galvanised steel, with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
- Pipework: complete pipework made of stainless steel, suitable for the connection of all conventional piping materials; the pipework is dimensioned according to the overall hydraulic performance of the pressure boosting system
- Pumps: 2 to 4 pumps switched in parallel of the Helix V 4 to Helix V 52 series; all pump parts that come in contact with the fluid are made of stainless steel for the Helix V 4 to V 16 series or of stainless steel/grey cast iron with cataphoretic coating for the Helix V 22 to Helix V 52 series; other versions on request. KTW/WRAS/ACS approval for parts that come in contact with the fluid
- Valves: Each pump is fitted on the suction and pressure side with a standard check valve with DVGW approval mark and on the pressure side with a DVGW/KTW-approved non-return valve.
- Diaphragm pressure vessel (accessories): 8 l/PN16 arranged on the discharge side with a diaphragm made of butyl rubber, with DVGW/KTW approval, completely safe in accordance with food safety laws; for testing and inspection purposes, with a shut-off ball cock with drain and throughflow fitting with DVGW/KTW approval in accordance with DIN 4807
- Pressure sensor: 4 to 20 mA, located on the discharge side for controlling the central Smart Controller SC
- Pressure indication: Pressure gauge (ø 63 mm) arranged on the discharge side; additional digital indication of the discharge pressure in the alphanumeric LC display of the Smart Controller SC
- Switchgear/controller: The system is equipped with a "Smart Controller" SC as standard; FC versions also equipped with a frequency converter


Materials

Helix V 4 to Helix V 16

- Impellers, diffusers, stage housing made of stainless steel 1.4307
- Pump housing of stainless steel 1.4301
- Shaft of stainless steel 1.4057
- 1.4404 shaft protection sleeve
- O-Ring gaskets made of EPDM (FKM gasket on request)
- Pipework made of 1.4301 stainless steel

Helix V 22 to Helix V 52

- Impellers, diffusers, stage housing made of stainless steel 1.4307
- Pump housing made of cataphoretically coated EN-GJL 250 grey cast iron
- Shaft of stainless steel 1.4057
- 1.4404 shaft protection sleeve
- O-Ring gaskets made of EPDM (FKM gasket on request)
- Pipework made of 1.4301 stainless steel


Scope of delivery

- Factory-mounted, connection-ready pressure boosting system checked for functionality and impermeability
- Packaging
- Installation and operating instructions


Planning guide

Inlet pressure

The maximum inlet pressure (see Technical data) is to be observed for the system configuration. The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum pump delivery head at Q = 0

Pressure reducer

Should the inlet pressure be too high or fluctuate too greatly, a pressure reducer must be installed to guarantee a constant minimum inlet pressure. The inlet pressure may fluctuate no more than 1.0 bar

Volume flow

Up to 240 m3/h (66 l/s) system configuration according to DIN 1988 (EN 806); with standby pump up to 320 m3/h (88 l/s) in the event of operation of the pump as an additional peak-load unit

Residual-current devices

When installing residual-current-operated protection switches in conjunction with frequency converters, bear in mind that only universal-current-sensitive residual-current-operated protection switches in accordance with DIN/VDE 0664 are to be fitted.

Wilo-WMS low-water cut-out switchgear

According to DIN 1988 (EN 806), the installation of a low-water cut-out switchgear is required if the pressure boosting systems are connected directly to a public mains power supply; this prevents the inlet pressure in the mains supply line from dropping to values below 1.0 bar. Please order directly when ordering the pressure boosting system. The WMS will then be installed in the pressure boosting system, electrically wired and fully tested by Wilo during the final functional test.

Standards/directives

The overall system conforms with the requirements of

- DIN 1988 Part 5
- DIN 1988 Part 6* (**)

* The specifications in DIN 1988 (EN 806) and of the water-supply companies are to be observed. Regarding the electrical components, the system conforms with the requirements of

- VDE 0100 Part 430/Part 540
- VDE 0110 Part 1/Part 2
- VDE 0660 Part 101/Part 107 and
- DIN 40719/IEC 754

Always observe the specifications in DIN 1988 (EN 806) when using and operating the pressure boosting system.(**) That does not apply to fire extinguishing systems in accordance with DIN 14462. Please request these separately.
Wilo UK
12 Wilo UK Products sorted by
Wilo UK Main Contact

Wilo UK
Second Avenue
Centrum 100
Burton upon Trent
DE14 2WJ
United Kingdom

Tel: 01283 523000

Certifications:

Other locations for this company:

About the Company

Wilo is one of the world’s leading manufacturers of pumps and pump systems for heating, air conditioning and cooling technology, as well as for water supplies and sewage treatment and disposal.
We're attending

Recommended Resellers:

blank
Recommended Installers: